There is an issue with the motor of your Cure Mega S? Before seeking external assistance or deciding to replace any spare parts, you can make an attempt at checking the motor. This article will guide you through simple steps to verify the motor cable connection.
1. Checking the Motor Connection
Power down and Prepare
- Turn off the curing unit and unplug the power cord
- Gently lay down the unit
- Use an Allen Wrench (size 2.5) to loosen the 10 screws and open the bottom case
Reconnect the motor cable
- Locate the motor cable connecting to the mainboard
- Reconnect the motor cable
Reassemble the device and Verify the motor functionality
- Tighten the 10 screws to reinstall the bottom case
- Insert the power cord and power on the curing unit
- Close the door of the curing unit
- Check if the curing unit can work normally
Contact Support
By following the above steps, you can easily reconnect the motor cable of your Cure Mega S. If you find any issues, feel free to reach out to Phrozen Support or your Authorized Reseller for further assistance. When contacting Phrozen Support, kindly send some photos or videos illustrating the issue.